EC&M Tech Talk — Rules for Measuring Earth Resistance

Jan. 3, 2024
In Episode 34, Randy Barnett addresses three main topics related to earth resistance.

In Episode 34 of EC&M Tech Talk, Electrical Trainer Randy Barnett covers three main points when it comes to earth resistance, also known as ground resistance. First, the National Electrical Code in Sec. 250.53 addresses a specific maximum resistance between a rod, pipe, or plate electrode and ground. However, there is no requirement to measure this resistance if a second ground rod is installed. The keys to understanding the need for minimum ground resistance are found in the performance requirements in Sec. 250.4. Dissipating voltage surges and stabilizing voltage during normal operation require proper grounding.  

The second topic in this Tech Talk  looks at practical applications that exceed NEC requirements. Randy provides an overview of grounding requirements for steel structures that support radio and antenna equipment, along with referencing the appropriate Telecommunications Industry Association standard. Substation grounding is much more complex than typical facility distribution grounding. While different options exist when designing a substation, the most common grounding method is the construction of a grid system. In both examples above, the earth resistance is typically first measured. The resistance from the grounding electrode system into the earth may be required to be a low as 10 ohms or less. Proper measurement and testing are required to ensure proper system operation and maintain safety. 

The final topic Randy covers shows the two most common methods to test earth resistance, which are the clamp-on method and the fall-of-potential method. He uses graphics to explain each method. Other test methods are also listed that may be used for specific applications along with the IEEE guide providing these methods.

About the Author

Randy Barnett | CEA

Randy Barnett is an NFPA Certified Electrical Safety Professional, a long-time journeyman electrician, instructor and author with expertise in industrial electrical construction and maintenance. He is Electrical Codes & Safety Manager for NTT Training. Because of his ability to develop and deliver quality programs, Randy has trained more than 10,000 students in all 50 states, including Canada, Singapore, Afghanistan, Dubai, Trinidad, and Saudi Arabi. His articles appear in numerous trade publications and, his book on "Commercial and Industrial Wiring" is used as an entry-level text in many electrician training programs. Randy also appears at various corporate and trade association speaking engagements and consults on training program design and implementation. Randy is a graduate of the U.S. Navy Nuclear Power School, served as a nuclear electrician in submarines and holds a B.S. in business.

Voice your opinion!

To join the conversation, and become an exclusive member of EC&M, create an account today!

Sponsored Recommendations

Chapter 9 of the NEC — Part 5

Calculating voltage drop with help from Table 8.

Choose Champion Elbows, Duct® and Strut™ to elevate project success

Learn how Champion Elbows, Duct® and Strut™ promote successful project outcomes in this flyer.

10 Reasons Why You Need Champion Strut

The Champion Strut™ system provides support for conduit and piping with strong, durable components.

Electrical Conduit Buyer's Guide

Industrial construction projects are on the rise. Are you ready to spec for success for your next job?